Power Distribution

///Power Distribution
Power Distribution 2017-09-13T01:47:40+00:00
More Information
Eaton STS Brochure

Eaton Static Transfer Switch (STS) (200-1000A)

The Eaton Type II STS transfers electrical loads from one source to another while eliminating the chance of a loss of power to critical equipment by properly coordinating with the electrical distribution system. During a fault condition, the Type II STS continues to conduct current, allowing downstream circuit breakers to work selectively. By incorporating the Eaton Type II STS into your power infrastructure many UPS/building configurations are possible.

  • Voltage 208Vac or 480Vac
  • Ensures instantaneous transfers without cross connection of sources via patented algorithm
  • Provides redundant internal power distribution in all system control boards
  • Improves system availability by enabling quick response to events through enhanced monitoring and diagnostics
  • Enables maintenance without affecting power to the critical load
  • Delivers high reliability and site-adaptability with digital signal processor-based technology
  • Eliminates fuse replacement with fuse-free, rugged and highly reliable SCR devices
  • Integrates with Eaton data center solutions
More Information
Eaton PDU Brochure
Eaton PDU Monitoring Brochure

Eaton Power Distribution Unit (PDU) (50-300 kVA)

The Eaton Power Distribution Unit (PDU) provides reliable data center power distribution for both raised and non-raised floor applications. To deliver effective power management and monitoring, the Eaton PDU incorporates the Eaton Energy Management System, optimizing both utilization and availability down to the branch circuit level. The optional Power Xpert Gateway PDP Card provides web-enabled, real-time monitoring for power quality status and fast response to power-related events. 

The Eaton PDU series can be easily expanded

as power needs change by adding up to three side-cars. This expands the distribution capacity from 84 to up to 252 circuit breaker pole positions. Each PDU can be configured to meet your specific needs for isolation, voltage transformation, harmonic reduction and voltage regulation with virtually limitless distribution options. Built-in system monitoring and diagnostics facilitate load balancing and warn of potential threats to your critical equipment.

  • Input: 208/380/400/415/480/600V, 3 phase (single and dual input)
  • Output: 208V, 3 phase 60 Hz
  • Distribution: 225A or 400A column panelboards
                          Main cabinet (front/rear access PDU only): 2 panelboards
                          Sidecar: 2 panelboards per cabinet
                          Up to 252 pole positions
                          Factory installed breakers
  • Offers a scalable architecture and space-saving design
  • Includes comprehensive monitoring and alarming with Eaton’s Energy Management System (EMS) and Power Xpert Software
  • Provides unparalleled ease of use through front-access only design, top and bottom cable access, and spacious wire-ways
  • Equipped with shunt trip for added safety
  • Integrates with Eaton data center solutions
More Information
Eaton RPP Brochure

Eaton Remote Power Panel (RPP)

Eaton RPPs deliver unmatched power distribution with up to 168 factory-installed branch breakers in a highly compact footprint. These products offer ease of installation through standard top and bottom cable entry provisions within a free standing structure. They include extensive monitoring options such as branch circuit monitoring to ensure effective monitoring and power management. The optional Power Xpert Gateway PDP Card provides web-enabled, real-time monitoring for power quality status and fast response to power-related events.

    • Voltage 208/120V or 400V versions, 3 phase
    • Direct connection to panelboard breakers (225A or 400A)
    • Distribution: 225A or 400A column panelboards
      Front: 2 panelboards
      Rear: 2 panelboards
      Up to 168 pole positions
      Factory installed breakers
  • Delivers unmatched power distribution with a highly compact footprint
  • Offers ease of installation through standard top and bottom cable entry provision
  • Includes extensive monitoring options allowing you to manage power effectively
  • Provides flexible expansion for your power distribution within a data center
More Information
Eaton Power Distribution Rack Brochure

Eaton Power Distribution Rack (PDR)

The Eaton Power Distribution Rack (PDR) offers a space-saving power distribution option for your data center. A key component of any complete power quality or power management solution, this flexible, high-density PDR was designed for the realities of modern data centers where floor space is costly, change is inevitable and uptime is critical.

  • Provides flexible power distribution with up to 168 factory-installed branch breakers in a highly compact footprint
  • Supports high-density racks with 400A panels and high power inputs
  • Allows free-standing unit with top and bottom cable entry for fast, flexible installation
  • Offers front and/or rear access, column power panels and large LCD for ease of servicing
  • Provides optional branch circuit monitoring to manage and monitor power down to individual circuits
More Information
Rack Power Module Datasheet

Eaton Rack Power Module (RPM)

The Eaton RPM simplifies data center power distribution by delivering up to 36 kW of power in a 3U cabinet. Connect directly from a three-phase UPS (such as the Eaton BladeUPS), or other utility source, to power secondary power distribution devices such as the Eaton ePDU. Twelve pole positions distribute power to completely customizable input and output configurations and voltages.

  • Provides plug-and-play primary distribution of power from a three-phase input source to secondary power distribution devices
  • Serves data center loads with various voltages, power cord configurations and layouts
  • Distributes three-phase power to 12 poles, grouped into two sets of six poles, with choice of output receptacle types
  • “Power Equalizer” LED display gives quick visual indication of each circuit’s load, reducing possibility of overloads and breakers tripped off line
  • Load information available from the front of the rack, no need to check individual power strips in the rear of the cabinet (hot isle)
  • Branch circuit monitoring option allows easy load monitoring over the network
  • Installs in only 3U of space in EIA 19” rack or enclosure (or wall-mounted), all hardware included
  • Enables customer installation and changes without the services of a licensed electrician
Click Here